 DRT-960 Series
Low Cost, Three-Phase 960W, DIN Rail Mount AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25C, 400 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
New Industrial Supplies!!
Conditions Min. 340 480 47 Cold Start 530 VAC Conditions Note 1 24 VDC Output 48 VDC Output Iout = 10% to 100% At Full Load, 400 VAC Input At Full Load, 500 VAC Input At Full Load At Full Load, 400 VAC Input At Full Load, 500 VAC Input Note 3 24 VDC Output 48 VDC Output TSW1 Note 5 TSW2 Note 5 0C to 50C Conditions Input - Output Input - FG (Frame Ground) Output - FG (Frame Ground) 500 VDC Conditions 105 30 59 105 80 Min. 24 48 0.5 0.5 200 200 60 14 30 80 150 36 66 115 90 Typ. Max. 555 780 63 3.5 Typ. 1.0 Max. 28 55 Units VAC VDC Hz A mA Units % VDC % % mSec mSec mSec mV Pk-Pk % VDC C %/C Max. Units VAC M
Key Features:
Input Parameter
Input Voltage Range * 960W Output Power * DIN Rail Mountable Input Frequency Range * Three-Phase, 4-Wire Input Inrush Current * UL 508 Approved Leakage Current * UL 60950 & EN 60950 App. Output * 24 VDC & 48 VDC Outputs Parameter * Cond./Rad. EMI Class B Output Voltage Accuracy * >122 kH MTBF Voltage Adjustment Range * LOW COST! Line Regulation Load Regulation Set Up Time Rise Time Hold Time Ripple & Noise (Note 2) Output Power Protection Over Voltage Protection (Note 4) Over Temperature Protection Temperature Coefficient General Parameter Isolation Voltage Isolation Resistance (Note 6) Environmental Parameter Operating Temperature Range Storage Temperature Range Operating Humidity Storage Humidity Vibration Physical Case Size Case Material Connection Weight Reliability Specifications Parameter MTBF Safety Standards Safety Approvals EMI Compliance Harmonic Current Compliance EMS Immunity Compliance
50
110 85 0.03 Typ.
Min. 3,000 1,500 500 100
RoHS Compliant
MicroPower Direct
232 Tosca Drive Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
Min. Typ. Max. Units -20 +25 +60 C -40 +85 C RH, Non-condensing 20 90 % RH, Non-condensing 10 95 % 10 ~ 500 Hz; 2G 10 min./1 Cycle; X, Y, Z axis each 1 hour Ambient 10.87 x 4.94 x 3.94 Inches (125.5 x 125.5 x 100.0 mm) Aluminum Screw Terminal 117.7 Oz (3.3 kg)
Min. Typ. Max. Units 122.5 kHours UL 508, UL 60950, EN 60950-1 UL, cUL, TUV Compliance to EN55011, EN55022 (CISPR22) Class B Compliance to EN6100-3-2,-3 EN6100-4-2,3,4,5,6,8,11; ENV50204;EN6100-6-2(EN50082-2) Heavy Ind. Level, criteria A
Conditions MIL HDBK 217F, 25C, Gnd Benign
Model Selection Guide
Model Number DRT-960-24 DRT-960-48 Rated Power (W) 960 960 Input Voltage (VAC) Range 340 - 555 340 - 555 Current (A) 400 VAC 2.0 2.0 500 VAC 1.6 1.6 Voltage (VDC) 24 48 Output Current (A) Max) 40 20 Current (A) Range 0 ~ 40 0 ~ 20 Efficiency (%, Typ) 91 92 Fuse Rating Slow-Blow (A) 6.3 6.3
Notes: 1. Output voltage tolerance includes set-up tolerance, line regulation and load regulation. 2. Ripple & noise is measured using equipment with 20 Mhz of bandwidth. Connection to the unit under test is made with a 12 inch length of "twisted pair" wires terminated with a set of 1.0 F & 4.7 F capacitors connected in parallel. 3. Overload protection is foldback current limiting. The unit recovers automatically when the fault is removed. 4. Over voltage protection is a clamp type. The power to the unit must be manually reset to recover. 5. Over temperature protection shuts down the output. The unit recovers automatically when the temperature goes down. For TSW1, the thermal detector is mounted on the heat sink of the power semiconductor. For TSW2, the thermal detector is mounted on the heat sink of the power Diode. 6. Isolation resistance is given for Input/Output; Input/FG and Output/FG. 7. To mount the unit to the DIN rail, tilt the unit rearwards from the top, fitting the mount over the top of the rail. Press back on the bottom front of the unit until it locks in place on the rail. To remove the unit from the rail, pull the removal clip at the bottom rear of the unit downward with a screw driver. With the clip down, lift up on the unit from the bottom front until it clears the rail. Before installation or removal all wiring should be disconnected and the main power to the system shut off. 8. When wiring the supply, all lines should be as thick and short as possible. AWG 14 wire is recommended for the DRT-960 series. 9. The units should be mounted so they are vertically orientated. Air flow (if it is provided) would optimally flow from the bottom to the top of the unit. 10. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating.
Derating Curve - Output Power vs Ambient Temperature
Static Characteristics
Mechanical Dimensions
Terminal Connections - TB1
Pin 1 2 3 4 Function AC/Lve 1 AC/Lve 2 AC/Live 3 Frame Ground (FG)
Terminal Connections - TB2
Pin 1,2 3,4 Function DC Output (+V) DC Output (-V)
Mechanical Notes:
* All dimensions are typical in inches (mm) * Tolerance x.xx = 0.01 (0.25)
MicroPower Direct
www.micropowerdirect.com
232 Tosca Drive Stoughton, MA 02072
*
TEL: (781) 344-8226
*
FAX: (781) 344-8481
*
E-Mail: sales@micropowerdirect.com


▲Up To Search▲   

 
Price & Availability of DRT-960

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X